Anasayfa / Ürünlerimiz / 6375 + 6220 DC Bias Current Source
Product Description:
LCR Meter collocates DC Bias 6220
LCR Meter Model 6375 6376 6377 6378 6379
LCR testing fuction ● ● ● ● ●
Highest Test Frequency(Hz) 200K 500K 1M 5M 10M
DC Bias Model 6220
DC Bias Bandwidth 200K 500K 1M 3M 3M
Highest Joining-up Current Output 120AMP
Constant Power Output Function ● ● ● ● ●
Interchangeable Positive and Negative Current Function ● ● ● ● ●
Large current DC Resistance Measurement ● ● ● ● ●
Current Graphic Scanning Analysis – – ● ● ●
Frequency Graphic Scanning Analysis – – ● ● ●
Temperature-rising Graphic Scanning Analysis ● ● ● ● ●
Measured Data
DC Bias Model 6210 6220 6240
Output Current 0.000A – 10.000A 0.000A – 20.000A 0.000A – 40.000A
Current Accuracy 0.000A – 1.000A 1%+5mA
1.001A – 5.000A 2%
5.001A – 20.000A 3%
Frequency 20Hz – 3MHz
Power Consumption 320W max 640W max
Specifications
Power Supply Voltage 88-264Vac
Frequency 47-63Hz
Interface RS-232, Handler (option)
Operation Auto、Manual、RS-232、GPIB (option)
Operation Environment Temperature : 10°C to 40°C Humidity : 20 ~ 90%
Dimension (W*H*D) 6210/6220 – 340x133x525 mm 、6240 – 432x132x552 mm
Weight 6210/6220 -15 Kg、6240 -20 Kg
Parameters Measurement Ranges
|Z| R X 0.1 mΩ – 100MΩ
|Y| G B 10nS – 1000S
Cs Cp 0.01pF – >1F
Ls Lp 0.01nH – 100KH
D 0.00001 – 9.9999
Q 0.1 – 9999.9
DCR 0.1mΩ – 100MΩ
Δ% -999.99% – 999.99%
Θ -180° – +180°
Applications
Resistance, Capacitance, Inductance, Oscillators, Sensors, Delay Line, Filters, ResonatorsProduct Description:
LCR Meter collocates DC Bias 6220
LCR Meter Model 6375 6376 6377 6378 6379
LCR testing fuction ● ● ● ● ●
Highest Test Frequency(Hz) 200K 500K 1M 5M 10M
DC Bias Model 6220
DC Bias Bandwidth 200K 500K 1M 3M 3M
Highest Joining-up Current Output 120AMP
Constant Power Output Function ● ● ● ● ●
Interchangeable Positive and Negative Current Function ● ● ● ● ●
Large current DC Resistance Measurement ● ● ● ● ●
Current Graphic Scanning Analysis – – ● ● ●
Frequency Graphic Scanning Analysis – – ● ● ●
Temperature-rising Graphic Scanning Analysis ● ● ● ● ●
Measured Data
DC Bias Model 6210 6220 6240
Output Current 0.000A – 10.000A 0.000A – 20.000A 0.000A – 40.000A
Current Accuracy 0.000A – 1.000A 1%+5mA
1.001A – 5.000A 2%
5.001A – 20.000A 3%
Frequency 20Hz – 3MHz
Power Consumption 320W max 640W max
Specifications
Power Supply Voltage 88-264Vac
Frequency 47-63Hz
Interface RS-232, Handler (option)
Operation Auto、Manual、RS-232、GPIB (option)
Operation Environment Temperature : 10°C to 40°C Humidity : 20 ~ 90%
Dimension (W*H*D) 6210/6220 – 340x133x525 mm 、6240 – 432x132x552 mm
Weight 6210/6220 -15 Kg、6240 -20 Kg
Parameters Measurement Ranges
|Z| R X 0.1 mΩ – 100MΩ
|Y| G B 10nS – 1000S
Cs Cp 0.01pF – >1F
Ls Lp 0.01nH – 100KH
D 0.00001 – 9.9999
Q 0.1 – 9999.9
DCR 0.1mΩ – 100MΩ
Δ% -999.99% – 999.99%
Θ -180° – +180°
Applications
Resistance, Capacitance, Inductance, Oscillators, Sensors, Delay Line, Filters, Resonators