+90 232 532 08 32
info@novatech-control.com

Microtest 5238 Transformer Tester

Anasayfa / Ürünlerimiz / Microtest 5238 Transformer Tester

Microtest 5238 Transformer Tester

Product Description:

5238  built-in Meter mode function will help you to save significantly on production facility cost, and because it could be used as a LCR power meter, you are able to elevate quality assurance and test method simultaneously i.e. leverage efficiency and lower facility cost.

MICROTEST transformer tester series offer exclusive fixture scan control kit that applies innovative CAT.5 network cable connection to simplify wiring structure and offer Open/Short calibration function, provide fixture zero-setting and high-frequency compensation functions to obtain higher accuracy for component testing. When the test frequency of the transformer becomes higher (higher than 200KHz), the interference from fixtures would also become bigger along with the test process going. Therefore, fixture zero-setting function is able to help the tester to acquire accurate measured values, which makes it become an indispensable device for quality assurance.

 

Basic Accuracy up to 0.1%

Support computer software connection and advanced software editing function

Innovative fixture zero-setting function to successfully prevent fixture interference from affecting the accuracy of measured values due to high test voltage

Able to test 30 items per second under fastest test speed. Elevate productivity significantly through auto-scan function

Paired with a 20-pin fixture to meet the test requirements for multi-pin network communication transformer

Optional 100mA DC Bias / 5×38 model is equipped with Meter Mode function / Support USB interface for data storag

Product Specification:

Measurement Data

 

Frequency         20Hz-200kHz (Meter Mode function)

Turn Ratio Frequency    50Hz ~ 200kHz (10Vac Max.)

Measurement Parameters         Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit

Basic Accuracy  ±0.1% (AC  parameter :  1KHz)

Output Impedance        100Ω

Frequency trimming resolution 5digits

Frequency output accuracy        ±0.01%

Point of Test      20 Points

ESR        Series/Parallel

Mathematical Mode      Absolute/Percentage

Calibration        Open Circuit/ Short Circuit/Load Calibration

Specifications

 

Power Supply    Voltage 90Vac ~ 125Vac or 190Vac ~ 250Vac

Frequency 48Hz ~ 62Hz

Display 320*240 dot-matrix display

Interface            RS-232, Handler (option), USB (option)

Flash Memory   64 sets

Operation          Auto、Manual、Remote Trigger

Environment     Temperature : 10℃ ~ 40℃     Humidity : 10% ~ 90%

Dimension (W*H*D)     360x133x420 (mm)

Weight 9 (Kg)

Parameters Measurement Ranges

 

Parameter         Range   Basic Accuracy

(AC  parameter :  1KHz) speed

L, LK      0.1nH ~ 9999.99H          0.1%    75ms

C            0.00001pF ~ 999.99mF  0.1%    75ms

Q,D       0.00001 ~ 99999             0.0005 75ms

Z,X,R     0.00001Ω ~ 99.9999MΩ              0.1%    75ms

Y            0.01nS ~ 99.9999S          0.1%    75ms

θ            -180°~ +180°     0.03°    75ms

DCR       0.01mΩ ~ 99.999MΩ     0.1%    25ms

Turn      0.01 ~ 99999.99turns    0.5%    75ms

Pin-Short            12 pairs, between pin to pin      —         25ms

Applications

 

Power transformer, Network communication transformer

​2017’de kurulan Novatech, elektronik sektöründe mümessillik hizmetleri, kağıt, plastik, lastik ve aluminyum sektörlerinde kalite kontrolü ve otomasyonu konularında danışmanlık ve teknik destek hizmetleri vermektedir.
İLETİŞİM BİLGİLERİ
Adres
Folkart Towers A-Blok Adalet Mah. Manas Bulv. No: 47 B/2601 35530
Telefon
+90 232 532 08 32
E-Posta
info@novatech-control.com