Anasayfa / Ürünlerimiz / Microtest MT-6910 Motor Stator Testing System
Product Description:
The MT-6910 motor stator test system collocates the MT-6910 and the 6905 tester. It is provided with eight 4-line independent measurement test points and 8 channels. The testing projects include the DC resistance tests which may detect the errors of copper wires that is over-tight during winding, broken or connecting. Besides, the Hipot testing on the required safety regulations, and the client respect project of the Impulse/Surge are included as well. With the most advanced Impulse/Surge tester takes waveform comparison to avoid the Corona Phenomenon that is caused by possible damage. It provides a complete solution of standard test project to the international manufacturers and serves as a further checker for your products. The motor stator test systems that match up the programmable interface and the simple operation can be quickly imported into the production lines and the quality control center.
Standard system is the Super Space-Saving Desktops Tester.
Optional system is the Systematic Modular Cabinet Tester.
Both the internal wire resistance and the contact resistance will not affect the measurement. Using the 4-wire measurement will be more accurate than others
To meet the standard test projects requirement of the international companies
To control and analysis the programs will reduce the human careless and misjudgment
Easy to edit environment and easy to learn
It can test multiple sets of DUTs simultaneously(depending on the number of winding set of the product)
When there are several DUTs are tested, it could identify the undesirable sets individually
The Impulse/Surge with waveform comparison is a non-destructive analysis
Maximum saved files will be up to 100 sets
It provides the password function
Speeding test could save time and improve efficiency
Chinese/English screen could be switched arbitrarily
Product Specification:
Measurement Data
DCR
Range 0.1mΩ ~ 100KΩ (4-wire measurement)
Accuracy Low Resistance:0.1mΩ ~ 1Ω ±( 0.2% ± 1mΩ)
High Resistance:1Ω ~ 100KΩ ±0.1%
Hipot
Voltage AC 0.1KV ~ 5KV DC 0.1KV ~ 6KV
Leakage Current AC 0 ~ 10mA DC 0 ~ 5mA
Arcing 0 ~ 9
Measurement Time 0.1 ~ 99.9 Continously Adjustable
Accuracy 3%
IR
Voltage 100V ~ 1000V ±5%
Range 1MΩ ~ 9.9GΩ
Measurement Time 0.1 ~ 99.9 Continously Adjustable
Accuracy 3%
Short Circuit
Voltage 0.2KV ~ 3KV ±2%
Measurement Item Total Area、Area size comparison、Flutter、Waveform comparison、Corona
Accuracy 2%
Using the DCR 4-wire Measurement
Both the internal wire resistance and the contact resistance will not affect the measurement. Using the 4-wire measurement will be more accurate than others.
Specification
Channel 8 channels
Indicator Pass/Fail Screen Diaplay/Sound
Fixture According to the test requirements
Power Supply 90 ~ 132Vac or 198 ~ 264Vac (selectable)
Interface RS-232
Flash Memory Storage of 100 rewritable data sets
Operation Manual、RS-232
Environment Temperature : 10°C ~ 40°C Humidity : 20 ~ 90%
6905 Dimension (W*H*D) / Weight 435x133x525 mm / 12.5 Kg
6917 Dimension (W*H*D) / Weight 435x178x525 mm / 15 Kg
6905 Display 128*64 dot-matrix display
6917 Display 320*240 dot-matrix display
Parameters Measurement Ranges